{"id":9613,"date":"2025-01-27T11:09:14","date_gmt":"2025-01-27T10:09:14","guid":{"rendered":"https:\/\/www.ace-engineering.nl\/energy-savings-and-control-with-parker-ac30-drives\/"},"modified":"2025-01-27T14:13:58","modified_gmt":"2025-01-27T13:13:58","slug":"energy-savings-and-control-with-parker-ac30-drives","status":"publish","type":"post","link":"https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/","title":{"rendered":"Energy Savings and Control with Parker AC30 Drives"},"content":{"rendered":"\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-2lhwio-a5445b4adee20013b2c80f5994a2243f\">\n.avia-image-container.av-2lhwio-a5445b4adee20013b2c80f5994a2243f img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-2lhwio-a5445b4adee20013b2c80f5994a2243f .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-2lhwio-a5445b4adee20013b2c80f5994a2243f av-styling- avia_animated_image av-animated-when-visible-95 zoom-in avia-align-center  avia-builder-el-0  el_before_av_font_icon  avia-builder-el-first '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img decoding=\"async\" fetchpriority=\"high\" class='wp-image-9588 avia-img-lazy-loading-not-9588 avia_image ' src=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives-1030x1030.jpg\" alt='Image of multiple industrial HVAC units with fans and ducts, accompanied by a Parker AC30 Variable Frequency Drive, showcasing its design and application in controlling machinery.' title='AC30 Variable frequency drives'  height=\"1030\" width=\"1030\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives-1030x1030.jpg 1030w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives-300x300.jpg 300w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives-100x100.jpg 100w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives-600x600.jpg 600w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives-80x80.jpg 80w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives-768x768.jpg 768w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives-36x36.jpg 36w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives-180x180.jpg 180w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives-705x705.jpg 705w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives-120x120.jpg 120w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives-450x450.jpg 450w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives.jpg 1350w\" sizes=\"(max-width: 1030px) 100vw, 1030px\" \/><\/div><\/div><\/div>\n<p>Precision and reliability are essential for controlling industrial machinery. Parker\u2019s AC30 Variable Frequency Drives are designed to give you exceptional levels of control and flexibility across various applications.<\/p>\n<h2>What Makes the AC30 Series Stand Out?<\/h2>\n<p>The AC30 Drives offer advanced control in a straightforward package. Whether you\u2019re managing simple fans and pumps or more complex systems, these drives get the job done. With a modular design, you can easily add communication and I\/O modules to suit your needs. This means the AC30 can handle both basic and more demanding applications with ease.<\/p>\n<p>Despite its impressive functionality, the AC30 is designed with simplicity in mind. Features like quick-start wizards, integrated application macros, and a multi-language graphical keypad make it accessible to users of all experience levels.<\/p>\n<p><a href=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/192_300022_AC30V_Catalog.pdf\"><strong>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-2x854w-d4700c2421ac57ba87c9fe41304baf1f\">\n.av_font_icon.av-2x854w-d4700c2421ac57ba87c9fe41304baf1f{\ncolor:#f6000f;\nborder-color:#f6000f;\n}\n.av_font_icon.av-2x854w-d4700c2421ac57ba87c9fe41304baf1f .av-icon-char{\nfont-size:20px;\nline-height:20px;\n}\n<\/style>\n<span  class='av_font_icon av-2x854w-d4700c2421ac57ba87c9fe41304baf1f avia_animate_when_visible av-icon-style- avia-icon-pos-left avia-icon-animate'><span class='av-icon-char' aria-hidden='true' data-av_icon='\ue875' data-av_iconfont='entypo-fontello' ><\/span><\/span>Download the AC30 Variable Speed Drive catalog<\/strong><\/a><\/p>\n<h2>Key Features and Benefits<\/h2>\n<h3><strong style=\"font-size: 20px;\">Flexibility<\/strong><\/h3>\n<p>The AC30 series supports both open-loop and closed-loop operation, giving you the freedom to choose the best setup for your application.<\/p>\n<p>Standard Ethernet Modbus TCP\/IP and options for industrial fieldbuses ensure seamless integration into your existing systems. Whether you prefer chassis-mounted or through-panel configurations, the AC30 has you covered.<\/p>\n<h3><strong style=\"font-size: 20px;\">Simplicity<\/strong><\/h3>\n<p>Parker\u2019s user-friendly design with features like:<\/p>\n<ul>\n<li>Parker Drive Quicktool (PDQ) software for easy configuration and monitoring<\/li>\n<li>Quick-start wizards to simplify setup<\/li>\n<li>A graphical keypad for intuitive navigation<\/li>\n<\/ul>\n<p>These features make it easy to get up and running, even if you\u2019re new to using frequency drives.<\/p>\n<h3><strong style=\"font-size: 20px;\">Reliability<\/strong><\/h3>\n<p>Designed to withstand harsh environments, the AC30 series offers conformal coating protection, isolated cooling systems, and advanced fault diagnostics. Features like the \u2018Black Box\u2019 trip recorder make troubleshooting quick and efficient.<\/p>\n<h3><strong style=\"font-size: 20px;\">Energy Efficiency<\/strong><\/h3>\n<p>The AC30 is engineered to optimize energy consumption without sacrificing performance. With intelligent pump and fan control algorithms, it can:<\/p>\n<ul>\n<li><strong><span style=\"color: #333333;\">Automatic belt breakage detection:<\/span> <\/strong>Interactive monitoring of the running conditions of a fan allows AC30 to detect a breakage in the drive belt between the fan and motor, stop the motor and indicate an alarm condition.<\/li>\n<li><strong><span style=\"color: #333333;\">Catching a spinning load &#8211; &#8220;fly-catching&#8221;:<\/span><\/strong> The fan control algorithms enable the AC30 to detect when a fan is free-wheeling and to regain control of it before running it at the commanded speed.<\/li>\n<li><strong><span style=\"color: #333333;\">PID Control:<\/span> <\/strong>Multiple PID control loops can be programmed to monitor process variables and adjust the speed of the motor accordingly to achieve the required variable setpoint.<\/li>\n<li><strong><span style=\"color: #333333;\">Intelligent Pump Profiles:<\/span><\/strong> Our advanced intelligent pump control algorithms monitor motor loads and provides users with a number of features designed specifically for pump control applications, such as :<br \/>\n&#8211; Pump dry running protection<br \/>\n&#8211; Flow detection (low and no-flow)<br \/>\n&#8211; Blocked pump detection<\/li>\n<li><strong><span style=\"color: #333333;\">Essential services (Fire mode):<\/span><\/strong> Selected via digital input, Fire mode will cause the drive to run continuously at the maximum programmed speed ignoring all other control signals and alarm conditions.<\/li>\n<li><strong><span style=\"color: #333333;\">Energy Optimisation:<\/span><\/strong> Under constant speed conditions, the motor power waveforms from the drive are optimised to reduce motor energy consumption without compromising performance.<\/li>\n<li><strong><span style=\"color: #333333;\">Skip Frequencies:<\/span><\/strong> Up to 4 speed and frequency bands can be programmed in the AC30, to enable resonant points on the fan to be avoided, reducing vibration, wear and noise.<\/li>\n<li><strong><span style=\"color: #333333;\">Timed Run Function:<\/span><\/strong> 10 daily start\/stop events can be programmed with different running speeds across a 7 day period. This function requires the optional Real Time Clock (RTC) module and is ideally suited to applications where regular operating patterns or periods of activity need to be accomodated, such as in a production environment.<\/li>\n<li><strong><span style=\"color: #333333;\">Process Timers:<\/span><\/strong> Multiple hours-run timers can be programmed to generate text alerts on the drive keypad to coincide with process maintenance intervals.<br \/>\nThese features help save energy and reduce operational costs over time.<\/li>\n<\/ul>\n<div  class='avia-video av-2d4z6o-09954d36aa3df851158e5b1e4e83fb2b avia-video-16-9 av-no-preview-image avia-video-load-always av-lazyload-immediate av-lazyload-video-embed'  itemprop=\"video\" itemtype=\"https:\/\/schema.org\/VideoObject\"  data-original_url='https:\/\/www.youtube.com\/watch?v=XzOoyTyI9fc'><script type='text\/html' class='av-video-tmpl'><div class='avia-iframe-wrap'><iframe loading=\"lazy\" title=\"AC30 Variable Speed Drives Overview | Parker Hannifin\" width=\"1500\" height=\"844\" src=\"https:\/\/www.youtube.com\/embed\/XzOoyTyI9fc?feature=oembed&autoplay=0&loop=0&controls=1&mute=0\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div><\/script><div class='av-click-to-play-overlay'><div class=\"avia_playpause_icon\"><\/div><\/div><\/div>\n<h2>Applications: Where Can You Use the AC30?<\/h2>\n<p>The versatility of the AC30 series makes it suitable for a wide range of industries and applications, including:<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/www.ace-engineering.nl\/en\/industries\/hvac-and-refrigeration\/\"><strong>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-6utnxs-ee5ac5ae12ec5c72dbb5cff3a29565a6\">\n.av_font_icon.av-6utnxs-ee5ac5ae12ec5c72dbb5cff3a29565a6{\ncolor:#f6000f;\nborder-color:#f6000f;\n}\n.av_font_icon.av-6utnxs-ee5ac5ae12ec5c72dbb5cff3a29565a6 .av-icon-char{\nfont-size:20px;\nline-height:20px;\n}\n<\/style>\n<span  class='av_font_icon av-6utnxs-ee5ac5ae12ec5c72dbb5cff3a29565a6 avia_animate_when_visible av-icon-style- avia-icon-pos-left avia-icon-animate'><span class='av-icon-char' aria-hidden='true' data-av_icon='\ue875' data-av_iconfont='entypo-fontello' ><\/span><\/span>HVAC systems<\/strong>:<\/a> Air conditioning, heating, ventilation, and refrigeration<\/p>\n<p><a href=\"https:\/\/www.ace-engineering.nl\/en\/industries\/industrial\/\"><strong>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-5we60w-3d6da6d8f087daae9599b75c974c6986\">\n.av_font_icon.av-5we60w-3d6da6d8f087daae9599b75c974c6986{\ncolor:#f6000f;\nborder-color:#f6000f;\n}\n.av_font_icon.av-5we60w-3d6da6d8f087daae9599b75c974c6986 .av-icon-char{\nfont-size:20px;\nline-height:20px;\n}\n<\/style>\n<span  class='av_font_icon av-5we60w-3d6da6d8f087daae9599b75c974c6986 avia_animate_when_visible av-icon-style- avia-icon-pos-left avia-icon-animate'><span class='av-icon-char' aria-hidden='true' data-av_icon='\ue875' data-av_iconfont='entypo-fontello' ><\/span><\/span>Industrial equipment:<\/strong><\/a> Pumps, fans, conveyors, centrifuges, and extruders<\/p>\n<p><a href=\"https:\/\/www.ace-engineering.nl\/en\/industries\/marine\/\"><strong>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-dtgmo-1bcc94baa195df462b2a813147b80333\">\n.av_font_icon.av-dtgmo-1bcc94baa195df462b2a813147b80333{\ncolor:#f6000f;\nborder-color:#f6000f;\n}\n.av_font_icon.av-dtgmo-1bcc94baa195df462b2a813147b80333 .av-icon-char{\nfont-size:20px;\nline-height:20px;\n}\n<\/style>\n<span  class='av_font_icon av-dtgmo-1bcc94baa195df462b2a813147b80333 avia_animate_when_visible av-icon-style- avia-icon-pos-left avia-icon-animate'><span class='av-icon-char' aria-hidden='true' data-av_icon='\ue875' data-av_iconfont='entypo-fontello' ><\/span><\/span>Marine and offshore<\/strong>:<\/a> Certified for challenging environments<\/p>\n<p><a href=\"https:\/\/www.ace-engineering.nl\/en\/industries\/food-and-beverage\/\"><strong>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-35sctc-346cc6ed31ee0998a85845ea4c39b663\">\n.av_font_icon.av-35sctc-346cc6ed31ee0998a85845ea4c39b663{\ncolor:#f6000f;\nborder-color:#f6000f;\n}\n.av_font_icon.av-35sctc-346cc6ed31ee0998a85845ea4c39b663 .av-icon-char{\nfont-size:20px;\nline-height:20px;\n}\n<\/style>\n<span  class='av_font_icon av-35sctc-346cc6ed31ee0998a85845ea4c39b663 avia_animate_when_visible av-icon-style- avia-icon-pos-left avia-icon-animate'><span class='av-icon-char' aria-hidden='true' data-av_icon='\ue875' data-av_iconfont='entypo-fontello' ><\/span><\/span>Food and beverage<\/strong>:<\/a> Reliable control for production lines<\/p>\n<p>With power ratings up to 450 kW and the ability to handle complex automation, the AC30 is a perfect fit for both standard and demanding applications.<\/p>\n<h2>Technical Excellence<\/h2>\n<p>The AC30 series is packed with technical features designed to meet modern industrial standards. Here are some highlights:<\/p>\n<ul>\n<li><strong><span style=\"color: #333333;\">High operating temperatures:<\/span> <\/strong>Handles up to 50\u00b0C<\/li>\n<li><strong><span style=\"color: #333333;\">Durable design:<\/span><\/strong> Tested for Hydrogen Sulphide (H2S) environments up to 25 ppm for 1,200 hours<\/li>\n<li><strong><span style=\"color: #333333;\">EMC compliance:<\/span><\/strong> Optional integrated EMC filters to meet C2 standards<\/li>\n<li><strong><span style=\"color: #333333;\">Advanced switching capabilities:<\/span><\/strong> Output frequencies up to 1,500 Hz<\/li>\n<li><strong><span style=\"color: #333333;\">Global certifications:<\/span><\/strong> CE, RoHS, and DNV Marine certification<\/li>\n<\/ul>\n<p>These specifications ensure that the AC30 can handle challenging conditions while maintaining the best performance.<\/p>\n<h2>Advanced Software Tools<\/h2>\n<p><a href=\"https:\/\/discover.parker.com\/AC_DC_Drives_Software\"><strong>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-2gvd5c-dbc2d84423ebd8a3c689c59e9e2392ea\">\n.av_font_icon.av-2gvd5c-dbc2d84423ebd8a3c689c59e9e2392ea{\ncolor:#f6000f;\nborder-color:#f6000f;\n}\n.av_font_icon.av-2gvd5c-dbc2d84423ebd8a3c689c59e9e2392ea .av-icon-char{\nfont-size:20px;\nline-height:20px;\n}\n<\/style>\n<span  class='av_font_icon av-2gvd5c-dbc2d84423ebd8a3c689c59e9e2392ea avia_animate_when_visible av-icon-style- avia-icon-pos-left avia-icon-animate'><span class='av-icon-char' aria-hidden='true' data-av_icon='\ue875' data-av_iconfont='entypo-fontello' ><\/span><\/span>Parker Drive Quicktool (PDQ)<\/strong><\/a><\/p>\n<p>PDQ is a powerful software platform for programming, monitoring, and diagnosing the AC30. With its intuitive wizards, PDQ simplifies:<\/p>\n<ul>\n<li>Initial setup<\/li>\n<li>Reconfiguration<\/li>\n<li>Parameter tuning<\/li>\n<\/ul>\n<h3>Parker Drive Developer (PDD)<\/h3>\n<p>For advanced users, PDD provides full PLC programming capabilities, supporting ladder logic, structured text, and function block diagrams. It\u2019s a versatile tool for creating custom drive solutions tailored to your application.<\/p>\n<h2>Contact Us Today!<\/h2>\n<p>Looking to upgrade your operations with the Parker AC30 Variable Frequency Drives? <a href=\"https:\/\/www.ace-engineering.nl\/en\/contact\/\"><strong>Contact us<\/strong><\/a> for more information or to place your order. Our team is ready to assist you in finding the perfect solution for your application. Don\u2019t miss the chance to bring advanced control and energy savings to your operations with the Parker AC30 series.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Precision and reliability are essential for controlling industrial machinery. Parker\u2019s AC30 Variable Frequency Drives are designed to give you exceptional levels of control and flexibility across various applications. What Makes the AC30 Series Stand Out? The AC30 Drives offer advanced control in a straightforward package. Whether you\u2019re managing simple fans and pumps or more complex [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":9588,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[745,733,748,741,728],"tags":[],"class_list":["post-9613","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-food-and-beverage-en","category-hvac-and-refrigeration","category-industrial-en","category-marine-en","category-parker-en"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Energy Savings and Control with Parker AC30 Drives - A&amp;C Engineering<\/title>\n<meta name=\"description\" content=\"Looking to upgrade your operations with the Parker AC30 Variable Frequency Drives? Find out why it is the perfect solution for you!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Energy Savings and Control with Parker AC30 Drives - A&amp;C Engineering\" \/>\n<meta property=\"og:description\" content=\"Looking to upgrade your operations with the Parker AC30 Variable Frequency Drives? Find out why it is the perfect solution for you!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/\" \/>\n<meta property=\"og:site_name\" content=\"A&amp;C Engineering\" \/>\n<meta property=\"article:published_time\" content=\"2025-01-27T10:09:14+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-27T13:13:58+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1350\" \/>\n\t<meta property=\"og:image:height\" content=\"1350\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"acewp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"acewp\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Energy Savings and Control with Parker AC30 Drives - A&amp;C Engineering","description":"Looking to upgrade your operations with the Parker AC30 Variable Frequency Drives? Find out why it is the perfect solution for you!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/","og_locale":"en_US","og_type":"article","og_title":"Energy Savings and Control with Parker AC30 Drives - A&amp;C Engineering","og_description":"Looking to upgrade your operations with the Parker AC30 Variable Frequency Drives? Find out why it is the perfect solution for you!","og_url":"https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/","og_site_name":"A&amp;C Engineering","article_published_time":"2025-01-27T10:09:14+00:00","article_modified_time":"2025-01-27T13:13:58+00:00","og_image":[{"width":1350,"height":1350,"url":"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives.jpg","type":"image\/jpeg"}],"author":"acewp","twitter_card":"summary_large_image","twitter_misc":{"Written by":"acewp","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/#article","isPartOf":{"@id":"https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/"},"author":{"name":"acewp","@id":"https:\/\/www.ace-engineering.nl\/#\/schema\/person\/5fbb82e7fceaf249a9d4d1c8c14a303a"},"headline":"Energy Savings and Control with Parker AC30 Drives","datePublished":"2025-01-27T10:09:14+00:00","dateModified":"2025-01-27T13:13:58+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/"},"wordCount":1528,"publisher":{"@id":"https:\/\/www.ace-engineering.nl\/#organization"},"image":{"@id":"https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives.jpg","articleSection":["Food &amp; Beverage","HVAC &amp; Refrigeration","Industrial","Marine","Parker"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/","url":"https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/","name":"Energy Savings and Control with Parker AC30 Drives - A&amp;C Engineering","isPartOf":{"@id":"https:\/\/www.ace-engineering.nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/#primaryimage"},"image":{"@id":"https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives.jpg","datePublished":"2025-01-27T10:09:14+00:00","dateModified":"2025-01-27T13:13:58+00:00","description":"Looking to upgrade your operations with the Parker AC30 Variable Frequency Drives? Find out why it is the perfect solution for you!","breadcrumb":{"@id":"https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/#primaryimage","url":"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives.jpg","contentUrl":"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2025\/01\/AC30-Variable-frequency-drives.jpg","width":1350,"height":1350,"caption":"Image of multiple industrial HVAC units with fans and ducts, accompanied by a Parker AC30 Variable Frequency Drive, showcasing its design and application in controlling machinery."},{"@type":"BreadcrumbList","@id":"https:\/\/www.ace-engineering.nl\/en\/energy-savings-and-control-with-parker-ac30-drives\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ace-engineering.nl\/"},{"@type":"ListItem","position":2,"name":"Energy Savings and Control with Parker AC30 Drives"}]},{"@type":"WebSite","@id":"https:\/\/www.ace-engineering.nl\/#website","url":"https:\/\/www.ace-engineering.nl\/","name":"A&C Engineering","description":"Engineering Solutions","publisher":{"@id":"https:\/\/www.ace-engineering.nl\/#organization"},"alternateName":"ACE Engineering","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ace-engineering.nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.ace-engineering.nl\/#organization","name":"A&C Engineering","alternateName":"ACE Engineering","url":"https:\/\/www.ace-engineering.nl\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ace-engineering.nl\/#\/schema\/logo\/image\/","url":"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/03\/AC-LOGO-Primair-transparant-background.png","contentUrl":"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/03\/AC-LOGO-Primair-transparant-background.png","width":4000,"height":2032,"caption":"A&C Engineering"},"image":{"@id":"https:\/\/www.ace-engineering.nl\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.ace-engineering.nl\/#\/schema\/person\/5fbb82e7fceaf249a9d4d1c8c14a303a","name":"acewp","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/67a3317a8082bc0f586c2e46f82a1617530cf674f2027a1a7d60fdff63a2c3e8?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/67a3317a8082bc0f586c2e46f82a1617530cf674f2027a1a7d60fdff63a2c3e8?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/67a3317a8082bc0f586c2e46f82a1617530cf674f2027a1a7d60fdff63a2c3e8?s=96&d=mm&r=g","caption":"acewp"},"url":"https:\/\/www.ace-engineering.nl\/en\/author\/acewp\/"}]}},"_links":{"self":[{"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/posts\/9613","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/comments?post=9613"}],"version-history":[{"count":0,"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/posts\/9613\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/media\/9588"}],"wp:attachment":[{"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/media?parent=9613"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/categories?post=9613"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/tags?post=9613"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}