{"id":7613,"date":"2024-04-15T08:14:32","date_gmt":"2024-04-15T07:14:32","guid":{"rendered":"https:\/\/www.ace-engineering.nl\/ode-solenoid-valves\/food-grade-solenoid-valves\/"},"modified":"2024-12-18T10:38:58","modified_gmt":"2024-12-18T09:38:58","slug":"food-grade-solenoid-valves","status":"publish","type":"page","link":"https:\/\/www.ace-engineering.nl\/en\/ode-solenoid-valves\/food-grade-solenoid-valves\/","title":{"rendered":"Food Grade Solenoid Valves"},"content":{"rendered":"<div id='av_section_1'  class='avia-section av-5ik4ni-58882cda49e76ef957e5221fc83e207f main_color avia-section-default avia-no-border-styling  avia-builder-el-0  el_before_av_contact  avia-builder-el-first  avia-bg-style-scroll container_wrap sidebar_right'  ><div class='container av-section-cont-open' ><main  role=\"main\" itemprop=\"mainContentOfPage\"  class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-7613'><div class='entry-content-wrapper clearfix'>\n\n<section  class='av_textblock_section av-luv9rp91-4291f4196be371414df3d5488dced859 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h1><span style=\"font-family: helvetica, arial, sans-serif;\">FOOD GRADE SOLENOID VALVES<\/span><\/h1>\n<\/div><\/section>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-4u42jy-f16d9824203e24266980dc7cb1d0a440\">\n.flex_column.av-4u42jy-f16d9824203e24266980dc7cb1d0a440{\nborder-radius:0px 0px 0px 0px;\npadding:30px 30px 30px 30px;\nbackground-color:#f4f4f4;\n}\n<\/style>\n<div  class='flex_column av-4u42jy-f16d9824203e24266980dc7cb1d0a440 av_two_third  avia-builder-el-3  el_after_av_textblock  el_before_av_one_third  first flex_column_div  column-top-margin'     ><p><section  class='av_textblock_section av-luv9lue6-0b0aa2cb042a6e1e53f5a9b639145888 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p><span style=\"font-family: helvetica, arial, sans-serif;\">Food grade solenoid valves are integral to the food and beverage industry, engineered to meet stringent sanitary standards for processing applications. Crafted from FDA-approved materials like stainless steel or food-grade plastics, these valves ensure product safety by preventing contamination.<\/span><\/p>\n<p><span style=\"font-family: helvetica, arial, sans-serif;\">Their design features smooth surfaces and minimal crevices, facilitating thorough cleaning and sanitation procedures to maintain hygiene standards. Compliance with industry regulations, such as NSF\/ANSI standards and FDA requirements, further ensures their suitability for food processing environments.<\/span><\/p>\n<p><span style=\"font-family: helvetica, arial, sans-serif;\">In addition to their sanitary design, food grade solenoid valves offer precise control over fluid flow, enabling accurate dosing of ingredients and additives. This level of control is vital for maintaining product quality and consistency in food and beverage production processes.<\/span><\/p>\n<p><span style=\"font-family: helvetica, arial, sans-serif;\">Overall, food grade solenoid valves play a crucial role in safeguarding the integrity of food and beverage products, providing reliable fluid control while upholding strict sanitary standards.<\/span><\/p>\n<\/div><\/section><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-luvaukry-5e2b238f409deff22ce1caf95d8d51ca\">\n#top .togglecontainer.av-luvaukry-5e2b238f409deff22ce1caf95d8d51ca p.toggler{\nbackground-color:#f4f4f4;\nborder-color:#f6000f;\n}\n#top .togglecontainer.av-luvaukry-5e2b238f409deff22ce1caf95d8d51ca .toggle_wrap .toggle_content{\nbackground-color:#f4f4f4;\nborder-color:#f6000f;\n}\n<\/style>\n<div  class='togglecontainer av-luvaukry-5e2b238f409deff22ce1caf95d8d51ca av-minimal-toggle  avia-builder-el-5  el_after_av_textblock  avia-builder-el-last ' >\n<section class='av_toggle_section av-2wxi31-ab24f087958d37fa43dcdf1428b19da9'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div role=\"tablist\" class=\"single_toggle\" data-tags=\"{All} \"  ><p id='toggle-toggle-id-1' data-fake-id='#toggle-id-1' class='toggler  av-title-above av-inherit-border-color'  itemprop=\"headline\"  role='tab' tabindex='0' aria-controls='toggle-id-1' data-slide-speed=\"200\" data-title=\"2\/2 way direct acting Technopolymer\" data-title-open=\"\" data-aria_collapsed=\"Click to expand: 2\/2 way direct acting Technopolymer\" data-aria_expanded=\"Click to collapse: 2\/2 way direct acting Technopolymer\">2\/2 way direct acting Technopolymer<span class=\"toggle_icon\"><span class=\"vert_icon\"><\/span><span class=\"hor_icon\"><\/span><\/span><\/p><div id='toggle-id-1' aria-labelledby='toggle-toggle-id-1' role='region' class='toggle_wrap  av-title-above'  ><div class='toggle_content invers-color av-inherit-border-color'  itemprop=\"text\" ><h3><span style=\"font-family: helvetica, arial, sans-serif;\">21AP series<\/span><\/h3>\n<div class=\"product-row\"><span style=\"font-family: helvetica, arial, sans-serif;\"><label>Type:<\/label>\u00a0Technopolymer Solenoid Valves<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Functioning:<\/label>\u00a02\/2 way direct acting, N.C.<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Port connection:<\/label>\u00a0G 1\/8, G 1\/4, Push-in \u00d8 4 mm, Push-in \u00d8 6 mm, Push-in \u00d8 8 mm<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Body material:<\/label>\u00a0PPS Technopolymer<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Flow Kv (l\/min):<\/label>\u00a01,1, 1,8, 2,5, 3,4<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Applications:<\/label>\u00a0Air, Coffee machines, Food&amp;Beverage, Industrial automation, Medical, Thermoregulation, Vending, Water<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Pressure M.O.P.D.:<\/label>\u00a0up to 25 bar<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Certifications:<\/label>\u00a0On Request<\/span><\/div>\n<div>\u00a0<\/div>\n<div>\n<h3><span style=\"font-family: helvetica, arial, sans-serif;\">21AP Series Push-in<\/span><\/h3>\n<div class=\"product-row\"><span style=\"font-family: helvetica, arial, sans-serif;\"><label>Type:<\/label>\u00a0Technopolymer Solenoid Valves<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Functioning:<\/label>\u00a02\/2 way direct acting, N.C.<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Port connection:<\/label>\u00a0Push-in \u00d8 4 mm, Push-in \u00d8 6 mm, Push-in \u00d8 8 mm<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Body material:<\/label>\u00a0PPS Technopolymer<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Flow Kv (l\/min):<\/label>\u00a01,1, 1,8, 2,5, 3,4<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Pressure M.O.P.D.:<\/label>\u00a0up to 16 bar<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Applications:<\/label>\u00a0Air, Coffee machines, Food&amp;Beverage, Industrial automation, Medical, Thermoregulation, Vending, Water<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Certifications:<\/label>\u00a0On Request<\/span><\/div>\n<div><a href=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/21AP5K1V15-T0-.pdf\">21AP5K1V15-T0 Data Sheet<\/a><\/div>\n<div>\n<div>\n<h3><span style=\"font-family: helvetica, arial, sans-serif;\">21KP Series<\/span><\/h3>\n<div class=\"product-row\"><span style=\"font-family: helvetica, arial, sans-serif;\"><label>Type:<\/label>\u00a0Technopolymer Solenoid Valves, Total Separation<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Functioning:<\/label>\u00a02\/2 way direct acting, Normally closed, Normally open<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Port connection:<\/label>\u00a0G 1\/8<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Body material:<\/label>\u00a0PSU<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Flow Kv (l\/min):<\/label>\u00a02,8<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Applications:<\/label>\u00a0Food&amp;Beverage, Industrial washing machines, Medical, Vending<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Certifications:<\/label>\u00a0On Request<\/span><\/div>\n<div><a href=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/21KPCF1KRS30-T0-.pdf\">21KPCF1KRS30-T0 Data Sheet<\/a><\/div>\n<div><a href=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/21KPAF1KRS30-T0-.pdf\">21KPAF1KRS30-T0 Data Sheet<\/a><\/div>\n<div>\n<h3><span style=\"font-family: helvetica, arial, sans-serif;\">AM Modular Series \u2013 Food Grade<\/span><\/h3>\n<div class=\"product-row\"><span style=\"font-family: helvetica, arial, sans-serif;\"><label>Type:<\/label>\u00a0Technopolymer Solenoid Valves<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Functioning:<\/label>\u00a02\/2 way direct acting, 3\/2 way direct acting<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Port connection:<\/label>\u00a0G 1\/8, \u00d8 6 mm ext. (hose connection)<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Body material:<\/label>\u00a0PPS Technopolymer<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Flow Kv (l\/min):<\/label>\u00a01,1, 1,8, 2,5, 3,4<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Applications:<\/label>\u00a0Air, Chemical, Food&amp;Beverage, Industrial automation, Medical, Packaging, Water<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Certifications:<\/label>\u00a0CE, MOCA, None<\/span><\/div>\n<div><a href=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/AM_eng.pdf\">AM Series Data Sheet<\/a><\/div>\n<div>\n<h3><span style=\"font-family: helvetica, arial, sans-serif;\">21APB series<\/span><\/h3>\n<div class=\"product-row\"><span style=\"font-family: helvetica, arial, sans-serif;\"><label>Type:<\/label>\u00a0Technopolymer Solenoid Valves<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Functioning:<\/label>\u00a02\/2 way direct acting, N.C.<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Port connection:<\/label>\u00a0Flange 30\u00d730<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Body material:<\/label>\u00a0PPS Technopolymer<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Flow Kv (l\/min):<\/label>\u00a00,45, 1,4, 2, 3,2, 4<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Pressure M.O.P.D.:<\/label>\u00a0up to 25 bar<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Applications:<\/label>\u00a0Air, Chemical, Coffee machines, Fuel gases, Medical, Steam, Vending, Water, Chemical\/Petrochemical<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Certifications:<\/label>\u00a0On Request<\/span><\/div>\n<div><a href=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/21APBK0R10-RP-.pdf\">21APBK0R10-RP Data Sheet<\/a><\/div>\n<div>\n<h3><span style=\"font-family: helvetica, arial, sans-serif;\">JM series<\/span><\/h3>\n<div class=\"product-row\"><span style=\"font-family: helvetica, arial, sans-serif;\"><label>Functioning:<\/label>\u00a02\/2 way direct acting<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Type:<\/label>\u00a0Technopolymer Solenoid Valves<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Port connection:<\/label>\u00a0G 1\/8 male, G 1\/8 female, \u00d8 6 mm ext. (hose connection), Fast fitting<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Body material:<\/label>\u00a0PPS Technopolymer<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Flow Kv (l\/min):<\/label>\u00a00,8, 2, 2,5<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Applications:<\/label>\u00a0Air, Coffee machines, Fuel gases, Industrial automation, Medical, Steam, Vending, Water<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Certifications:<\/label>\u00a0On Request<\/span><\/div>\n<div><a href=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/23MA1VBGBGBG-_.pdf\">23MA1VBGBGBG Data Sheet<\/a><\/div>\n<div><a href=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/23MA1VBDBDBD-.pdf\">23MA1VBDBDBD Data Sheet<\/a><\/div>\n<div><a href=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/23MA1BVABABA-_.pdf\">23MA1BVABABA Data Sheet<\/a><\/div>\n<div>\n<h3><span style=\"font-family: helvetica, arial, sans-serif;\">21JP series<\/span><\/h3>\n<div class=\"product-row\"><span style=\"font-family: helvetica, arial, sans-serif;\"><label>Type:<\/label>\u00a0Technopolymer Solenoid Valves<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Functioning:<\/label>\u00a02\/2 way direct acting, N.C.<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Port connection:<\/label>\u00a0plug in connection, G 1\/8 male, G 1\/8 female, \u00d8 6 mm ext. (hose connection)<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Body material:<\/label>\u00a0PPS Technopolymer<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Flow Kv (l\/min):<\/label>\u00a01, 2,1<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Applications:<\/label>\u00a0Air, Coffee machines, Food&amp;Beverage, Industrial automation, Medical, Vending, Water<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Certifications:<\/label>\u00a0On Request, WRAS<\/span><\/div>\n<div><a href=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/21JP1R0V23.pdf\">21JP1R0V23 Data Sheet<\/a><\/div>\n<div><a href=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/21JPBR0V12-.pdf\">21JPBR0V12 Data Sheet<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><\/section>\n<section class='av_toggle_section av-468di5-303de69bb77537506bf8e5f52f372449'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div role=\"tablist\" class=\"single_toggle\" data-tags=\"{All} \"  ><p id='toggle-toggle-id-2' data-fake-id='#toggle-id-2' class='toggler  av-title-above av-inherit-border-color'  itemprop=\"headline\"  role='tab' tabindex='0' aria-controls='toggle-id-2' data-slide-speed=\"200\" data-title=\"2\/2 way proportional Technopolymer\" data-title-open=\"\" data-aria_collapsed=\"Click to expand: 2\/2 way proportional Technopolymer\" data-aria_expanded=\"Click to collapse: 2\/2 way proportional Technopolymer\">2\/2 way proportional Technopolymer<span class=\"toggle_icon\"><span class=\"vert_icon\"><\/span><span class=\"hor_icon\"><\/span><\/span><\/p><div id='toggle-id-2' aria-labelledby='toggle-toggle-id-2' role='region' class='toggle_wrap  av-title-above'  ><div class='toggle_content invers-color av-inherit-border-color'  itemprop=\"text\" ><h3><span style=\"font-family: helvetica, arial, sans-serif;\">21AP Proportional<\/span><\/h3>\n<div class=\"product-row\"><span style=\"font-family: helvetica, arial, sans-serif;\"><label>Type:<\/label>\u00a0Technopolymer Solenoid Valves<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Functioning:<\/label>\u00a02\/2 way proportional acting, N.C.<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Port connection:<\/label>\u00a0G 1\/8<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Body material:<\/label>\u00a0PPS Technopolymer<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Flow Kv (l\/min):<\/label>\u00a01,1, 3,4<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Applications:<\/label>\u00a0Air, Coffee machines, Food&amp;Beverage, Industrial automation, Medical, Thermoregulation, Vending, Water<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Certifications:<\/label>\u00a0On Request<\/span><\/div>\n<div>\u00a0<\/div>\n<\/div><\/div><\/div><\/section>\n<section class='av_toggle_section av-2cfz5p-433b5ed81bf1050c3be7bd8fae6658f5'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div role=\"tablist\" class=\"single_toggle\" data-tags=\"{All} \"  ><p id='toggle-toggle-id-3' data-fake-id='#toggle-id-3' class='toggler  av-title-above av-inherit-border-color'  itemprop=\"headline\"  role='tab' tabindex='0' aria-controls='toggle-id-3' data-slide-speed=\"200\" data-title=\"2\/2 way direct acting Brass\" data-title-open=\"\" data-aria_collapsed=\"Click to expand: 2\/2 way direct acting Brass\" data-aria_expanded=\"Click to collapse: 2\/2 way direct acting Brass\">2\/2 way direct acting Brass<span class=\"toggle_icon\"><span class=\"vert_icon\"><\/span><span class=\"hor_icon\"><\/span><\/span><\/p><div id='toggle-id-3' aria-labelledby='toggle-toggle-id-3' role='region' class='toggle_wrap  av-title-above'  ><div class='toggle_content invers-color av-inherit-border-color'  itemprop=\"text\" ><h3><span style=\"font-family: helvetica, arial, sans-serif;\">21A Series \u2013 Food Grade<\/span><\/h3>\n<div class=\"product-row\"><span style=\"font-family: helvetica, arial, sans-serif;\"><label>Type:<\/label>\u00a0NSF Food Grade Solenoid Valves<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Functioning:<\/label>\u00a02\/2 way direct acting, Normally closed, Normally open<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Port connection:<\/label>\u00a0G 1\/8, G 1\/4<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Body material:<\/label>\u00a0Brass<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Flow Kv (l\/min):<\/label>\u00a00,45, 1,4, 2, 3,2, 4, 6,5, 9<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Applications:<\/label>\u00a0Coffee machines, Food&amp;Beverage, Vending, Water<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Certifications:<\/label>\u00a0On Request<\/span><\/div>\n<div>\n<h3><span style=\"font-family: helvetica, arial, sans-serif;\">21JB-JN Series<\/span><\/h3>\n<div class=\"product-row\"><span style=\"font-family: helvetica, arial, sans-serif;\"><label>Type:<\/label>\u00a0General Purpose Solenoid Valves<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Functioning:<\/label>\u00a02\/2 way direct acting, N.C., N.O.<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Port connection:<\/label>\u00a0G 1\/8, M5<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Body material:<\/label>\u00a0Brass, Low leed brass<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Flow Kv (l\/min):<\/label>\u00a01, 1,1, 2, 2,3<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Applications:<\/label>\u00a0Air, Coffee machines, Compressors, Fuel gases, Industrial automation, Industrial washing machines, Vending, Water, Water treatment<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Certifications:<\/label>\u00a0On Request<\/span><\/div>\n<div><a href=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/gen-catalog-page_21JB-JN-1.pdf\">21JB-JN Series General Catalog<\/a><\/div>\n<\/div>\n<\/div><\/div><\/div><\/section>\n<section class='av_toggle_section av-3nm5f1-679a899ea6c4ec6eaf0122074998c5c5'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div role=\"tablist\" class=\"single_toggle\" data-tags=\"{All} \"  ><p id='toggle-toggle-id-4' data-fake-id='#toggle-id-4' class='toggler  av-title-above av-inherit-border-color'  itemprop=\"headline\"  role='tab' tabindex='0' aria-controls='toggle-id-4' data-slide-speed=\"200\" data-title=\"3\/2 way direct acting Brass\" data-title-open=\"\" data-aria_collapsed=\"Click to expand: 3\/2 way direct acting Brass\" data-aria_expanded=\"Click to collapse: 3\/2 way direct acting Brass\">3\/2 way direct acting Brass<span class=\"toggle_icon\"><span class=\"vert_icon\"><\/span><span class=\"hor_icon\"><\/span><\/span><\/p><div id='toggle-id-4' aria-labelledby='toggle-toggle-id-4' role='region' class='toggle_wrap  av-title-above'  ><div class='toggle_content invers-color av-inherit-border-color'  itemprop=\"text\" ><h3><span style=\"font-family: helvetica, arial, sans-serif;\">31A Series<\/span><\/h3>\n<div class=\"product-row\"><span style=\"font-family: helvetica, arial, sans-serif;\"><label>Type:<\/label>\u00a0General Purpose Solenoid Valves<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Functioning:<\/label>\u00a03\/2 way direct acting, N.C., N.O.<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Port connection:<\/label>\u00a0flanged, G 1\/8, G 1\/4, 1\/4 NPT<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Body material:<\/label>\u00a0Brass, Low leed brass<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Flow Kv (l\/min):<\/label>\u00a00,45, 0,7, 0,8, 1,4, 2, 3,2, 4, 6,5<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Applications:<\/label>\u00a0Air, Coffee machines, Industrial automation, Packaging, Steam, Thermoregulation, Vending, Water, Water treatment<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Certifications:<\/label>\u00a0On Request<\/span><\/div>\n<div>\u00a0<\/div>\n<\/div><\/div><\/div><\/section>\n<section class='av_toggle_section av-3a3e9p-6795eb3d9f6de8ae55df61c95b08e62d'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div role=\"tablist\" class=\"single_toggle\" data-tags=\"{All} \"  ><p id='toggle-toggle-id-5' data-fake-id='#toggle-id-5' class='toggler  av-title-above av-inherit-border-color'  itemprop=\"headline\"  role='tab' tabindex='0' aria-controls='toggle-id-5' data-slide-speed=\"200\" data-title=\"3\/2 way direct acting Technopolymer\" data-title-open=\"\" data-aria_collapsed=\"Click to expand: 3\/2 way direct acting Technopolymer\" data-aria_expanded=\"Click to collapse: 3\/2 way direct acting Technopolymer\">3\/2 way direct acting Technopolymer<span class=\"toggle_icon\"><span class=\"vert_icon\"><\/span><span class=\"hor_icon\"><\/span><\/span><\/p><div id='toggle-id-5' aria-labelledby='toggle-toggle-id-5' role='region' class='toggle_wrap  av-title-above'  ><div class='toggle_content invers-color av-inherit-border-color'  itemprop=\"text\" ><h3><span style=\"font-family: helvetica, arial, sans-serif;\">31APB series Food Grade<\/span><\/h3>\n<div class=\"product-row\"><span style=\"font-family: helvetica, arial, sans-serif;\"><label>Type:<\/label>\u00a0Technopolymer Solenoid Valves<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Functioning:<\/label>\u00a03\/2 way direct acting, N.C.<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Port connection:<\/label>\u00a0Flange<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Body material:<\/label>\u00a0PPS Technopolymer<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Applications:<\/label>\u00a0Air, Chemical, Coffee machines, Fuel gases, Medical, Steam, Vending, Water, Chemical\/Petrochemical<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Flow Kv (l\/min):<\/label>\u00a00,45, 1,4, 2, 3,2, 4<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Certifications:<\/label>\u00a0On Request<\/span><\/div>\n<div>\n<h3><span style=\"font-family: helvetica, arial, sans-serif;\">Series 31AP Push-in<\/span><\/h3>\n<div class=\"product-row\"><span style=\"font-family: helvetica, arial, sans-serif;\"><label>Type:<\/label>\u00a0Technopolymer Solenoid Valves<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Functioning:<\/label>\u00a03\/2 way direct acting, Normally closed<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Body material:<\/label>\u00a0PPS Technopolymer<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Port connection:<\/label>\u00a0Push-in \u00d8 4 mm, Push-in \u00d8 6 mm, Push-in \u00d8 8 mm<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Flow Kv (l\/min):<\/label>\u00a01,1, 1,8, 2,5, 3,4<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Certifications:<\/label>\u00a0On Request<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Applications:<\/label>\u00a0Coffee machines, Vending<\/span><\/div>\n<div>\n<h3><span style=\"font-family: helvetica, arial, sans-serif;\">Series 31JP Push-in<\/span><\/h3>\n<div class=\"product-row\"><span style=\"font-family: helvetica, arial, sans-serif;\"><label>Type:<\/label>\u00a0Technopolymer Solenoid Valves<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Functioning:<\/label>\u00a03\/2 way direct acting, N.C.<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Port connection:<\/label>\u00a0Push-in \u00d8 4 mm, Push-in \u00d8 6 mm<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Body material:<\/label>\u00a0PPS Technopolymer<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Flow Kv (l\/min):<\/label>\u00a00,75, 2,1<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Applications:<\/label>\u00a0Coffee machines, Food&amp;Beverage, Industrial automation, Medical, Vending<\/span><br \/>\n<span style=\"font-family: helvetica, arial, sans-serif;\"><label>Certifications:<\/label>\u00a0On Request<\/span><\/div>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><\/section>\n<\/div><\/p><\/div>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-9654e-5caf635b3b7092cf7facd7054c6ee09e\">\n.flex_column.av-9654e-5caf635b3b7092cf7facd7054c6ee09e{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n<\/style>\n<div  class='flex_column av-9654e-5caf635b3b7092cf7facd7054c6ee09e av_one_third  avia-builder-el-6  el_after_av_two_third  avia-builder-el-last  flex_column_div av-zero-column-padding  column-top-margin'     ><p>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-luvcnhi0-15f38a9dd53a3725e2ef5a96d9284578\">\n.avia-image-container.av-luvcnhi0-15f38a9dd53a3725e2ef5a96d9284578 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-luvcnhi0-15f38a9dd53a3725e2ef5a96d9284578 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-luvcnhi0-15f38a9dd53a3725e2ef5a96d9284578 av-styling- avia-align-center  avia-builder-el-7  el_before_av_toggle_container  avia-builder-el-first '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img decoding=\"async\" fetchpriority=\"high\" class='wp-image-3047 avia-img-lazy-loading-not-3047 avia_image ' src=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/Food-Grade-Solenoid-Valves-1030x1030.jpg\" alt='' title='Food Grade Solenoid Valves'  height=\"1030\" width=\"1030\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/Food-Grade-Solenoid-Valves-1030x1030.jpg 1030w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/Food-Grade-Solenoid-Valves-300x300.jpg 300w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/Food-Grade-Solenoid-Valves-80x80.jpg 80w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/Food-Grade-Solenoid-Valves-768x768.jpg 768w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/Food-Grade-Solenoid-Valves-1536x1536.jpg 1536w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/Food-Grade-Solenoid-Valves-2048x2048.jpg 2048w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/Food-Grade-Solenoid-Valves-36x36.jpg 36w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/Food-Grade-Solenoid-Valves-180x180.jpg 180w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/Food-Grade-Solenoid-Valves-1500x1500.jpg 1500w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/Food-Grade-Solenoid-Valves-705x705.jpg 705w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/Food-Grade-Solenoid-Valves-120x120.jpg 120w, https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/Food-Grade-Solenoid-Valves-450x450.jpg 450w\" sizes=\"(max-width: 1030px) 100vw, 1030px\" \/><\/div><\/div><\/div><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-luvaukry-24-afd3870915f541b19484bae1125d6305\">\n#top .togglecontainer.av-luvaukry-24-afd3870915f541b19484bae1125d6305 p.toggler{\nborder-color:#f6000f;\n}\n#top .togglecontainer.av-luvaukry-24-afd3870915f541b19484bae1125d6305 .toggle_wrap .toggle_content{\nborder-color:#f6000f;\n}\n<\/style>\n<div  class='togglecontainer av-luvaukry-24-afd3870915f541b19484bae1125d6305 av-elegant-toggle  avia-builder-el-8  el_after_av_image  avia-builder-el-last ' >\n<section class='av_toggle_section av-589jml-5af8f60c878d0bc12152ae7893e0c531'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div role=\"tablist\" class=\"single_toggle\" data-tags=\"{All} \"  ><p id='toggle-toggle-id-6' data-fake-id='#toggle-id-6' class='toggler  av-title-above av-inherit-border-color'  itemprop=\"headline\"  role='tab' tabindex='0' aria-controls='toggle-id-6' data-slide-speed=\"200\" data-title=\"Catalogs\" data-title-open=\"\" data-aria_collapsed=\"Click to expand: Catalogs\" data-aria_expanded=\"Click to collapse: Catalogs\">Catalogs<span class=\"toggle_icon\"><span class=\"vert_icon\"><\/span><span class=\"hor_icon\"><\/span><\/span><\/p><div id='toggle-id-6' aria-labelledby='toggle-toggle-id-6' role='region' class='toggle_wrap  av-title-above'  ><div class='toggle_content invers-color av-inherit-border-color'  itemprop=\"text\" ><p><a href=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/Brochure_Industrial_ENG_compressed-1-2.pdf\" download=\"\"><br \/>\nBrochure Industrial<br \/>\n<\/a><\/p>\n<\/div><\/div><\/div><\/section>\n<section class='av_toggle_section av-4ifjot-ea349d5ae134a6523d599a3c3c6428e0'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div role=\"tablist\" class=\"single_toggle\" data-tags=\"{All} \"  ><p id='toggle-toggle-id-7' data-fake-id='#toggle-id-7' class='toggler  av-title-above av-inherit-border-color'  itemprop=\"headline\"  role='tab' tabindex='0' aria-controls='toggle-id-7' data-slide-speed=\"200\" data-title=\"Information\" data-title-open=\"\" data-aria_collapsed=\"Click to expand: Information\" data-aria_expanded=\"Click to collapse: Information\">Information<span class=\"toggle_icon\"><span class=\"vert_icon\"><\/span><span class=\"hor_icon\"><\/span><\/span><\/p><div id='toggle-id-7' aria-labelledby='toggle-toggle-id-7' role='region' class='toggle_wrap  av-title-above'  ><div class='toggle_content invers-color av-inherit-border-color'  itemprop=\"text\" ><p><a href=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/General-Information-2.pdf\" download=\"\"><br \/>\nGeneral Information<br \/>\n<\/a><\/p>\n<\/div><\/div><\/div><\/section>\n<section class='av_toggle_section av-280if1-3a041127054ec8e980391d7de398ad20'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div role=\"tablist\" class=\"single_toggle\" data-tags=\"{All} \"  ><p id='toggle-toggle-id-8' data-fake-id='#toggle-id-8' class='toggler  av-title-above av-inherit-border-color'  itemprop=\"headline\"  role='tab' tabindex='0' aria-controls='toggle-id-8' data-slide-speed=\"200\" data-title=\"Instruction Sheets\" data-title-open=\"\" data-aria_collapsed=\"Click to expand: Instruction Sheets\" data-aria_expanded=\"Click to collapse: Instruction Sheets\">Instruction Sheets<span class=\"toggle_icon\"><span class=\"vert_icon\"><\/span><span class=\"hor_icon\"><\/span><\/span><\/p><div id='toggle-id-8' aria-labelledby='toggle-toggle-id-8' role='region' class='toggle_wrap  av-title-above'  ><div class='toggle_content invers-color av-inherit-border-color'  itemprop=\"text\" ><p><a href=\"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/04\/standard-solenoid-valves-instruction-sheet_300037.pdf\" download=\"\"><br \/>\nStandard Solenoid Valves Instruction Sheet<br \/>\n<\/a><\/p>\n<\/div><\/div><\/div><\/section>\n<\/div><\/p><\/div><\/div><\/div><\/main><!-- close content main element --><\/div><\/div><div id='after_section_1'  class='main_color av_default_container_wrap container_wrap sidebar_right'  ><div class='container av-section-cont-open' ><div class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-7613'><div class='entry-content-wrapper clearfix'><form action=\"https:\/\/www.ace-engineering.nl\/en\/ode-solenoid-valves\/food-grade-solenoid-valves\/\" method=\"post\" data-fields-with-error=\"Found errors in the following field(s):\" class=\"avia_ajax_form av-form-labels-visible   avia-builder-el-9  el_after_av_section  avia-builder-el-no-sibling   \" data-avia-form-id=\"1\" data-avia-redirect=''  aria-label='Contactformulier' ><h3 class=''>Request a quote<\/h3><fieldset><p class='  first_form  form_element form_fullwidth' id='element_avia_1_1'><label for=\"avia_1_1\">Name <abbr class=\"required\" title=\"required\">*<\/abbr><\/label> <input name=\"avia_1_1\" class=\"text_input is_empty\" type=\"text\" id=\"avia_1_1\" value=\"\" \/><\/p><p class='  first_form  form_element form_fullwidth' id='element_avia_2_1'><label for=\"avia_2_1\">Company <abbr class=\"required\" title=\"required\">*<\/abbr><\/label> <input name=\"avia_2_1\" class=\"text_input is_empty\" type=\"text\" id=\"avia_2_1\" value=\"\" \/><\/p><p class='  first_form  form_element form_fullwidth' id='element_avia_3_1'><label for=\"avia_3_1\">E-mail <abbr class=\"required\" title=\"required\">*<\/abbr><\/label> <input name=\"avia_3_1\" class=\"text_input is_email\" type=\"text\" id=\"avia_3_1\" value=\"\" \/><\/p><p class='  first_form  form_element form_fullwidth' id='element_avia_4_1'><label for=\"avia_4_1\">Article number <abbr class=\"required\" title=\"required\">*<\/abbr><\/label> <input name=\"avia_4_1\" class=\"text_input is_empty\" type=\"text\" id=\"avia_4_1\" value=\"\" \/><\/p><p class='  first_form  form_element form_fullwidth' id='element_avia_5_1'><label for=\"avia_5_1\">Number <abbr class=\"required\" title=\"required\">*<\/abbr><\/label> <input name=\"avia_5_1\" class=\"text_input is_empty\" type=\"text\" id=\"avia_5_1\" value=\"\" \/><\/p><p class='  first_form  form_element form_fullwidth av-last-visible-form-element' id='element_avia_6_1'><label for=\"avia_6_1\" class=\"textare_label hidden textare_label_avia_6_1\">Additional Information <abbr class=\"required\" title=\"required\">*<\/abbr><\/label><textarea  name=\"avia_6_1\" class=\"text_area is_empty\" cols=\"40\" rows=\"7\" id=\"avia_6_1\" ><\/textarea><\/p><p class=\"hidden\"><input type=\"text\" name=\"avia_7_1\" class=\"hidden \" id=\"avia_7_1\" value=\"\" \/><\/p><p class=\"form_element \"><input type=\"hidden\" value=\"1\" name=\"avia_generated_form1\" \/><input type=\"submit\" value=\"Send\" class=\"button\"  data-sending-label=\"Sending\"\/><\/p><\/fieldset><\/form><div id=\"ajaxresponse_1\" class=\"ajaxresponse ajaxresponse_1 hidden\"><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":7493,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-7613","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Food Grade Solenoid Valves - A&amp;C Engineering<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ace-engineering.nl\/ode-solenoid-valves\/food-grade-solenoid-valves\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Food Grade Solenoid Valves - A&amp;C Engineering\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ace-engineering.nl\/ode-solenoid-valves\/food-grade-solenoid-valves\/\" \/>\n<meta property=\"og:site_name\" content=\"A&amp;C Engineering\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-18T09:38:58+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Food Grade Solenoid Valves - A&amp;C Engineering","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ace-engineering.nl\/ode-solenoid-valves\/food-grade-solenoid-valves\/","og_locale":"en_US","og_type":"article","og_title":"Food Grade Solenoid Valves - A&amp;C Engineering","og_url":"https:\/\/www.ace-engineering.nl\/ode-solenoid-valves\/food-grade-solenoid-valves\/","og_site_name":"A&amp;C Engineering","article_modified_time":"2024-12-18T09:38:58+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.ace-engineering.nl\/ode-solenoid-valves\/food-grade-solenoid-valves\/","url":"https:\/\/www.ace-engineering.nl\/ode-solenoid-valves\/food-grade-solenoid-valves\/","name":"Food Grade Solenoid Valves - A&amp;C Engineering","isPartOf":{"@id":"https:\/\/www.ace-engineering.nl\/#website"},"datePublished":"2024-04-15T07:14:32+00:00","dateModified":"2024-12-18T09:38:58+00:00","breadcrumb":{"@id":"https:\/\/www.ace-engineering.nl\/ode-solenoid-valves\/food-grade-solenoid-valves\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ace-engineering.nl\/ode-solenoid-valves\/food-grade-solenoid-valves\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ace-engineering.nl\/ode-solenoid-valves\/food-grade-solenoid-valves\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ace-engineering.nl\/"},{"@type":"ListItem","position":2,"name":"ODE","item":"https:\/\/www.ace-engineering.nl\/en\/ode-solenoid-valves\/"},{"@type":"ListItem","position":3,"name":"Food Grade Solenoid Valves"}]},{"@type":"WebSite","@id":"https:\/\/www.ace-engineering.nl\/#website","url":"https:\/\/www.ace-engineering.nl\/","name":"A&C Engineering","description":"Engineering Solutions","publisher":{"@id":"https:\/\/www.ace-engineering.nl\/#organization"},"alternateName":"ACE Engineering","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ace-engineering.nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.ace-engineering.nl\/#organization","name":"A&C Engineering","alternateName":"ACE Engineering","url":"https:\/\/www.ace-engineering.nl\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ace-engineering.nl\/#\/schema\/logo\/image\/","url":"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/03\/AC-LOGO-Primair-transparant-background.png","contentUrl":"https:\/\/www.ace-engineering.nl\/wp-content\/uploads\/2024\/03\/AC-LOGO-Primair-transparant-background.png","width":4000,"height":2032,"caption":"A&C Engineering"},"image":{"@id":"https:\/\/www.ace-engineering.nl\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/pages\/7613","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/comments?post=7613"}],"version-history":[{"count":0,"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/pages\/7613\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/pages\/7493"}],"wp:attachment":[{"href":"https:\/\/www.ace-engineering.nl\/en\/wp-json\/wp\/v2\/media?parent=7613"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}